Your browser is no longer supported. Please upgrade your browser to improve your experience.

Hyperion Turbidity

Valeport’s Hyperion Turbidity sensor delivers high-performance measurements of turbidity, in a compact & robust package ideal as a standalone sensor, for ROV and AUV integration or used as part of a multi-sensor array and data logger.

Hyperion Turbidity is essentially two sensors in one.

The first is a “classic” turbidity sensor, a nephelometer that uses a 90° beam angle, for low turbidity levels (0 to 1,000 NTU).

The second, for high turbidity levels (1,000 to 6,000 NTU), uses an Optical Backscatter (OBS) arrangement (~120° beam angle). Intelligent sampling and use of a 24 bit ADC eliminates the need to gain switch at higher turbidity levels.

The optical head is very compact – measuring just 20mm in diameter and with a full ocean depth rating lends itself to OEM type solutions. Offered as standard in a 6000m depth rated, titanium housing the Hyperion Fluorometer has a wide range (9-30V DC) isolated power supply, data output up to 16Hz and RS232 communications.

Support

Hyperion Turbidity Datasheet
Hyperion Optical Sensors Operating Manual
Technical drawings

Software

Valeport Configure
Valeport Configure App Software Operating Manual

Technical Specifications

Turbidity

Dynamic Range
Nephelometer: 0 to >1 ,000 NTU - linear response OBS: 0 to >6,000 NTU - linear response
>6,000 NTU has a non-linear monotonic response that allows derivation of higher values using look-up tables
Linearity
0.99 R2
Minimum Detection Level
0.03 NTU (Nephelometer)

Physical

Materials:
Titanium with Sapphire glass Optical window
Depth Rating:
6000m
Dimensions:
40mmØ x 179.5mm (including connector)
Weight:
0.50 kg (in air)
0.26 kg (in water)
Operating Temp:
-5°C - 35°C
(the sensor is damaged above 60°C)

Communications

The instrument will operate in real time, with set up performed by direct communications with a PC before and after deployment

RS232 / RS485 / Modbus RTU
Up to 200m cable
Direct to serial port via USB adapter
Baud Rate:
2400 - 115200
Protocol:
8 data bits, 1 stop bit, No parity, No flow control

Electrical

External:
9 – 28V DC Isolated
Power:
<600mW
Connector:
SubConn MCBH6F

Software

Valeport Configure has been introduced to simplify the configuration of instruments prior to deployment.

Valeport Configure
2.0.31

Ordering

0901002-T
Hyperion Turbidity
Supplied with:
· 1x Hyperion Instrument
· 1x 0.5m pig tail
· Manual and transit case
· Valeport Configure Software

Product Enquiry

Name(Required)